Modular Office 1
Specification Overview
Specification Overview
• Full BCAR Procedures followed as a shadow programme
• TGD Compliance (excluding Renewables)
• A2 BER rating
Structure
• Superstructure to have design life of 60 Years. In accordance with BS 7543:2005
Minimum U-Value Specification
• External Walls U-value 0.18W/Mk
• Floor U-value 0.18W/Mk
• Roof U-value 0.2W/Mk
• Windows and Doors U-value
• 1.2W/Mk
Airtightness
• Maximum air permeability level of
5m3/hr/m2 @50 Pa
Ventilation
• In compliance with Technical Guidance
Document Part F
Heating
• Electric Heaters to be fitted to all rooms
Hot Water
• Undercounter water heater for Kitchen sink and Basin, Electric Shower
Electrical
• Electrical installation to be RECI Certified
ENERGY EFFICIENT
Up to 67pc less energy than traditional builds
COST EFFECTIVE
Huge build savings up to 500%
ECO FRIENDLY
Very low carbon footprint living
INSTANT BUILD
Pod homes come prebuilt
TECHNICAL SPECIFICATION
Space & Water Heating:
Space Heating: 4no. thermostatically controlled Dimplex Quantum wall mounted radiators.
Hot Water:
Compact thermostatically controlled under counter electric instantaneous A rated water heater. 7.5Kw electric shower, 10 bar pressure, max flow rate 3Ltr/min.
Electrical:
Electrical installation to be RECI certified. LED fittings & bulbs, ceiling mounted pendants throughout. White bakelite sockets & switches, 450mm above FFL, 1350mm above FFL.
Ventilation:
Background ventilation, in compliance with TGD part F
Blackout Blinds:
Reveal mounted manual fabric roller blackout blinds to all areas